PS-2000 Multichannel Inspection system

Motorized Scanner

PS-2000 with Scanner

12¡¯ pipe MIC crack



Ferrous and Non-ferrous metal tube¸¦ ¿Ü°æÀ¸·Î ºÎÅÍ ¸Å¿ì ºü¸£°í Á¤È®ÇÏ°Ô °Ë»ç

Low Frequency Electromagnetic Technique (LFET)±â¼úÀ» ±â¹ÝÀ¸·Î ÇÑ 8ä³ÎÀÇ Àåºñ
MIC (microbiological induced corrosion) Attack, FAC (Flow Accelerated Corrosion), cracking, erosion, corrosion, and pitting wall lossesµî °ËÃâ Àü󸮰¡ ÇÊ¿ä ¾ø´Ù.
Through coating inspection Á¢Ã˸ÅÁúÀÌ ÀüÇô ÇÊ¿ä ¾ø°í ÃÖ¼ÒÇÑÀÇ Å©¸®´× ÈÄ ¹Ù·Î °Ë»ç °¡´É.

ÁÖ¿ä Àû¿ëºÐ¾ß
 


Service Water Piping, Fire Protection, Coal Mill Piping, and virtually any piping with access to the pipe O.D. In addition to piping, pressure vessels and heat exchanger shells.

ÁÖ¿ä»ç¾ç

 Inspects straight sections and bends

 Minimal pipe preparation

 Wide frequency range 5Hz to 30KHz

 Real-Time Display

 Low signal to noise ratio

 Inspects through coatings

 Scanner sizes 625¡±(16.1mm)and greater

 Can be used with TesTex L.F.E.T  Crawler

 Cable lengths of up to 50¡¯ (15m)

 Small modular PC based design

 Inspects through I.D. or O.D. scale

 Windows based software